//Sterilization Chamber => Tank 2, used for sterilizing the water
|
|
// -> Handle the Sterilization Chamber and Post UV on storage
|
|
// -> Dependency: water bank's float switch Low and High
|
|
// chamber's float switch Low and High
|
|
// storage's float switch Low and High
|
|
|
|
#define CHAMBER_STATE_NONE 0
|
|
#define CHAMBER_STATE_IDLE 1
|
|
#define CHAMBER_STATE_START_FILLING 2
|
|
#define CHAMBER_STATE_CHECK_FILLING_TO_LOWER 3
|
|
#define CHAMBER_STATE_CHECK_FILLING_TO_UPPER 4
|
|
#define CHAMBER_STATE_STERILIZING 5
|
|
#define CHAMBER_STATE_START_UNLOAD 6
|
|
#define CHAMBER_STATE_START_UNLOAD_TO_LOWER 7
|
|
#define CHAMBER_STATE_START_UNLOAD_TO_UPPER 8
|
|
|
|
//uint32_t chamberSterilizationOzoneDuration = 1*60*1000;
|
|
uint32_t chamberSterilizationUvDuration = 5*60*1000;
|
|
//uint32_t chamberSterilizationPostUvDuration = 5*60*1000;
|
|
|
|
uint32_t chamberExpectedTimeToFilledLower = 1*60*1000;//in mulliseconds
|
|
uint32_t chamberExpectedTimeToFilledUpper = 3*60*1000;//in mulliseconds
|
|
uint32_t chamberExpectedTimeToUnloadFilledLower = 1*60*1000;//in mulliseconds
|
|
uint32_t chamberExpectedTimeToUnloadFilledUpper = 3*60*1000;//in mulliseconds
|
|
uint32_t chamberTick = 0;
|
|
bool chamberPostUvEnable = true;
|
|
uint32_t chamberPostUvDuration = 1*60*1000;
|
|
uint32_t chamberPostUvTick = 0;
|
|
uint32_t chamberInverterStartupTick = 0;
|
|
|
|
int chamberState = WATER_BANK_STATE_NONE;
|
|
bool chamberAutomatic = false;
|
|
|
|
#define CHAMBER_ERROR_NONE 0
|
|
#define CHAMBER_ERROR_LOWER_FLOAT_SWITCH 1 //lower switch error
|
|
#define CHAMBER_ERROR_UPPER_FLOAT_SWITCH 2 //upper switch error
|
|
#define CHAMBER_ERROR_UPPER_FLOAT_SWITCH_OR_NO_WATER 3
|
|
#define CHAMBER_ERROR_LOWER_FLOAT_SWITCH_OR_NO_WATER 4
|
|
#define CHAMBER_ERROR_STORAGE_LOWER_FLOAT_SWITCH 5 //lower switch error
|
|
#define CHAMBER_ERROR_STORAGE_UPPER_FLOAT_SWITCH 6 //upper switch error
|
|
#define CHAMBER_ERROR_STORAGE_UPPER_FLOAT_SWITCH_OR_NO_WATER 7
|
|
#define CHAMBER_ERROR_STORAGE_LOWER_FLOAT_SWITCH_OR_NO_WATER 8
|
|
#define CHAMBER_ERROR_TANK_LOWER_FLOAT_SWITCH 9 //lower switch error
|
|
#define CHAMBER_ERROR_TANK_UPPER_FLOAT_SWITCH 10 //upper switch error
|
|
#define CHAMBER_ERROR_TANK_UPPER_FLOAT_SWITCH_OR_NO_WATER 11
|
|
#define CHAMBER_ERROR_TANK_LOWER_FLOAT_SWITCH_OR_NO_WATER 12
|
|
#define CHAMBER_ERROR_LOWER_FLOAT_SWITCH_OR_LEAKED 13
|
|
|
|
bool chamberError = false;
|
|
byte chamberErrorCode = CHAMBER_ERROR_NONE;
|
|
String chamberErrorString = "";
|
|
|
|
//penampungan hasil sterilisasi (tank 3)
|
|
bool chamber_SterilizedLowerFloatSwitchStateCurrent = false;
|
|
bool chamber_SterilizedLowerFloatSwitchStatePrevious = false;
|
|
bool chamber_SterilizedUpperFloatSwitchStateCurrent = false;
|
|
bool chamber_SterilizedUpperFloatSwitchStatePrevious = false;
|
|
//ruang sterilisasi
|
|
bool chamber_SterilizationLowerFloatSwitchStateCurrent = false;
|
|
bool chamber_SterilizationLowerFloatSwitchStatePrevious = false;
|
|
bool chamber_SterilizationUpperFloatSwitchStateCurrent = false;
|
|
bool chamber_SterilizationUpperFloatSwitchStatePrevious = false;
|
|
//water tank sebelum sterilisasi
|
|
bool chamber_TankLowerFloatSwitchStateCurrent = false;
|
|
bool chamber_TankLowerFloatSwitchStatePrevious = false;
|
|
bool chamber_TankUpperFloatSwitchStateCurrent = false;
|
|
bool chamber_TankUpperFloatSwitchStatePrevious = false;
|
|
|
|
bool chamberSterilizationSuccess = false;
|
|
|
|
uint32_t GetSterilizationRemainingMillis(){
|
|
uint32_t t = 0;
|
|
if (chamberState==CHAMBER_STATE_STERILIZING){
|
|
t = (chamberSterilizationOzoneDuration - (millis()-chamberTick));
|
|
if (t>chamberSterilizationOzoneDuration) t = 0;
|
|
return t;
|
|
}
|
|
|
|
if (GetSwitchState(STERILIZED_UV_SWITCH)){
|
|
t = chamberPostUvDuration - (millis()-chamberPostUvTick);
|
|
if (t>chamberPostUvDuration) t = 0;
|
|
}
|
|
return t;
|
|
}
|
|
|
|
bool OnOzoneStrelization(){
|
|
if (GetSwitchState(STERILIZATION_OZONE_AND_UV_SWITCH)) return true;
|
|
return (chamberState==CHAMBER_STATE_STERILIZING);
|
|
}
|
|
|
|
bool OnPostUV(){
|
|
if (GetSwitchState(STERILIZED_UV_SWITCH)){
|
|
return true;
|
|
}
|
|
return false;
|
|
}
|
|
|
|
bool IsChamberFilling(){
|
|
return (chamberState>=CHAMBER_STATE_START_FILLING) && (chamberState<=CHAMBER_STATE_CHECK_FILLING_TO_UPPER);
|
|
}
|
|
|
|
bool IsChamberUnload(){
|
|
return (chamberState>=CHAMBER_STATE_START_UNLOAD) && (chamberState<=CHAMBER_STATE_START_UNLOAD_TO_UPPER);
|
|
}
|
|
|
|
bool ChamberIsSuccess(){
|
|
return chamberSterilizationSuccess;
|
|
}
|
|
|
|
bool ChamberIsError(){
|
|
return chamberError;
|
|
}
|
|
|
|
String ChamberErrorString(){
|
|
if (chamberError) return chamberErrorString;
|
|
return "";
|
|
}
|
|
|
|
bool ChamberIsIdle(){
|
|
return (chamberState==CHAMBER_STATE_IDLE) || (chamberState==WATER_BANK_STATE_NONE);
|
|
}
|
|
|
|
bool IsChamberSystemRunning(){
|
|
if (GetSwitchState(STERILIZATION_OZONE_AND_UV_SWITCH) || GetSwitchState(INVERTER_SWITCH)) return true;
|
|
if (!chamberAutomatic) return (chamberState!=WATER_BANK_STATE_NONE);
|
|
return (chamberState>CHAMBER_STATE_IDLE);
|
|
}
|
|
|
|
void ClearChamberError(){
|
|
chamberError = false;
|
|
chamberErrorCode = CHAMBER_ERROR_NONE;
|
|
chamberErrorString = "";
|
|
}
|
|
|
|
void ChamberTurnOffAllSwitch(bool exceptInverterAndPostUv=true){
|
|
//make sure ozone, cycling pump, fill in pump, fill out pump, uv1, uv2 is off
|
|
//inverter
|
|
if (!exceptInverterAndPostUv){
|
|
if (GetSwitchState(INVERTER_SWITCH)){
|
|
Serial.println("ChamberSystemRoutine: INVERTER_SWITCH OFF");
|
|
SetSwitchState(INVERTER_SWITCH, false);
|
|
}
|
|
}
|
|
//ozone
|
|
if (GetSwitchState(STERILIZATION_OZONE_AND_UV_SWITCH)){
|
|
Serial.println("ChamberSystemRoutine: STERILIZATION_OZONE_AND_UV_SWITCH OFF");
|
|
SetSwitchState(STERILIZATION_OZONE_AND_UV_SWITCH, false);
|
|
}
|
|
//post uv
|
|
if (!exceptInverterAndPostUv){
|
|
if (GetSwitchState(STERILIZED_UV_SWITCH)){
|
|
Serial.println("ChamberSystemRoutine: ");
|
|
SetSwitchState(STERILIZED_UV_SWITCH, false);
|
|
}
|
|
}
|
|
//fill in pump
|
|
if (GetSwitchState(STERILIZATION_CHAMBER_FILL_PUMP_SWITCH)){
|
|
Serial.println("ChamberSystemRoutine: STERILIZATION_CHAMBER_FILL_PUMP_SWITCH OFF");
|
|
SetSwitchState(STERILIZATION_CHAMBER_FILL_PUMP_SWITCH, false);
|
|
}
|
|
//fill out pump
|
|
if (GetSwitchState(STERILIZED_CHAMBER_FILL_PUMP_SWITCH)){
|
|
Serial.println("ChamberSystemRoutine: STERILIZED_CHAMBER_FILL_PUMP_SWITCH OFF");
|
|
SetSwitchState(STERILIZED_CHAMBER_FILL_PUMP_SWITCH, false);
|
|
}
|
|
//circulation pump
|
|
if (GetSwitchState(STERILIZATION_CHAMBER_CIRCULATION_PUMP_SWITCH)){
|
|
Serial.println("ChamberSystemRoutine: STERILIZATION_CHAMBER_CIRCULATION_PUMP_SWITCH OFF");
|
|
SetSwitchState(STERILIZATION_CHAMBER_CIRCULATION_PUMP_SWITCH, false);
|
|
}
|
|
}
|
|
|
|
//system running state =====================================================
|
|
void ChamberSystemRoutine(){
|
|
|
|
//handle the post uv timer independently ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
|
|
bool ctrlLowerSwitchState = GetInSwitchState(STERILIZED_CHAMBER_FLOAT_SWITCH_LOWER);
|
|
if ((!ctrlLowerSwitchState) || ((GetSwitchState(STERILIZED_UV_SWITCH) && (millis()-chamberPostUvTick)>=chamberPostUvDuration)) || (!chamberPostUvEnable)){
|
|
if (GetSwitchState(STERILIZED_UV_SWITCH)){
|
|
Serial.println("ChamberSystemRoutine: ");
|
|
SetSwitchState(STERILIZED_UV_SWITCH, false);
|
|
}
|
|
//if ((chamberState==CHAMBER_STATE_NONE) || (chamberState==CHAMBER_STATE_IDLE) || ((chamberState>=CHAMBER_STATE_START_FILLING) && (chamberState<=CHAMBER_STATE_START_FILLING_TO_UPPER))){
|
|
if (chamberState==CHAMBER_STATE_NONE){
|
|
//ChamberTurnOffAllSwitch(false);//turn off all
|
|
}else if ((chamberState!=CHAMBER_STATE_NONE) && (chamberState!=CHAMBER_STATE_STERILIZING)){
|
|
SetSwitchState(STERILIZED_UV_SWITCH, false);//turn off post uv
|
|
SetSwitchState(INVERTER_SWITCH, false);//turn off inverter
|
|
//ChamberTurnOffAllSwitch(false);//turn off all
|
|
}
|
|
}
|
|
//~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
|
|
|
|
switch(chamberState){
|
|
case CHAMBER_STATE_NONE:{
|
|
ChamberTurnOffAllSwitch(true);
|
|
};
|
|
break;
|
|
case CHAMBER_STATE_IDLE:{
|
|
//this is the state when use automatic mode
|
|
ChamberTurnOffAllSwitch(true); //except inverter if post uv if running
|
|
|
|
//in case mismatch, prevent auto monitoring
|
|
if (!chamberAutomatic){
|
|
chamberState = CHAMBER_STATE_NONE;
|
|
Serial.println("CHAMBER_STATE_IDLE -> CHAMBER_STATE_NONE");
|
|
}
|
|
|
|
//trigger condition:
|
|
// state => STORAGE_STATE_CHECK_IF_EMPTY: sterilized bank is empty
|
|
chamber_SterilizedLowerFloatSwitchStateCurrent = GetInSwitchState(STERILIZED_CHAMBER_FLOAT_SWITCH_LOWER);
|
|
bool intoFilling = false;
|
|
if ((chamber_SterilizedLowerFloatSwitchStateCurrent!=chamber_SterilizedLowerFloatSwitchStatePrevious) && (!chamber_SterilizedLowerFloatSwitchStateCurrent)){
|
|
intoFilling = true;
|
|
Serial.println("CHAMBER_STATE_IDLE -> Trigger reason: Storage empty");
|
|
}
|
|
//storage kosong dan water tank menjadi penuh
|
|
chamber_TankLowerFloatSwitchStateCurrent = GetInSwitchState(WATER_BANK_FLOAT_SWITCH_LOWER);
|
|
chamber_TankUpperFloatSwitchStateCurrent = GetInSwitchState(WATER_BANK_FLOAT_SWITCH_UPPER);
|
|
if (!chamber_SterilizedLowerFloatSwitchStateCurrent && (chamber_TankUpperFloatSwitchStateCurrent!=chamber_TankUpperFloatSwitchStatePrevious) && (chamber_TankUpperFloatSwitchStateCurrent && chamber_TankLowerFloatSwitchStateCurrent)){
|
|
intoFilling = true;
|
|
//Serial.println("Tank baru penuh dan pemampungan sterilisasi kosong.");
|
|
Serial.println("CHAMBER_STATE_IDLE -> Trigger reason: Storage empty and Water Tank just full");
|
|
}
|
|
//update state
|
|
chamber_SterilizedLowerFloatSwitchStatePrevious = chamber_SterilizedLowerFloatSwitchStateCurrent;
|
|
chamber_TankLowerFloatSwitchStatePrevious = chamber_TankLowerFloatSwitchStateCurrent;
|
|
chamber_TankUpperFloatSwitchStatePrevious = chamber_TankUpperFloatSwitchStateCurrent;
|
|
if (intoFilling){
|
|
chamberSterilizationSuccess = false;
|
|
ClearChamberError();
|
|
chamberState = CHAMBER_STATE_START_FILLING;
|
|
Serial.println("CHAMBER_STATE_IDLE -> CHAMBER_STATE_START_FILLING");
|
|
}
|
|
};
|
|
break;
|
|
case CHAMBER_STATE_START_FILLING:{
|
|
chamberSterilizationSuccess = false;
|
|
chamber_SterilizedLowerFloatSwitchStateCurrent = GetInSwitchState(STERILIZED_CHAMBER_FLOAT_SWITCH_LOWER);
|
|
chamber_SterilizedUpperFloatSwitchStateCurrent = GetInSwitchState(STERILIZED_CHAMBER_FLOAT_SWITCH_UPPER);
|
|
//cek error lain dari float switch:
|
|
// -> storage switch upper lower harus benar
|
|
// -> tank switch upper lower harus benar (water tank penuh)
|
|
|
|
//cek penampungan harus kosong
|
|
if (chamber_SterilizedLowerFloatSwitchStateCurrent){
|
|
//switch back to idle
|
|
chamberError = true;
|
|
chamberErrorString = "Penampungan harus kosong dahulu untuk memulai sterilisasi.";
|
|
chamberState = CHAMBER_STATE_IDLE;
|
|
Serial.print("Error: ");
|
|
Serial.println(chamberErrorString);
|
|
Serial.println("CHAMBER_STATE_START_FILLING -> CHAMBER_STATE_IDLE");
|
|
return;
|
|
}
|
|
//check if: full -> CHAMBER_STATE_STERILIZING
|
|
// empty -> CHAMBER_STATE_CHECK_FILLING_TO_LOWER
|
|
// lower -> CHAMBER_STATE_CHECK_FILLING_TO_UPPER
|
|
//jika chamber penuh langsung ke sterilisasi
|
|
chamber_SterilizationLowerFloatSwitchStateCurrent = GetInSwitchState(STERILIZATION_CHAMBER_FLOAT_SWITCH_LOWER);
|
|
chamber_SterilizationUpperFloatSwitchStateCurrent = GetInSwitchState(STERILIZATION_CHAMBER_FLOAT_SWITCH_UPPER);
|
|
if (chamber_SterilizationLowerFloatSwitchStateCurrent && chamber_SterilizationUpperFloatSwitchStateCurrent){
|
|
chamberTick = millis();
|
|
chamberState = CHAMBER_STATE_STERILIZING;
|
|
Serial.println("Sterilization chamber already full.");
|
|
Serial.println("CHAMBER_STATE_START_FILLING -> CHAMBER_STATE_STERILIZING");
|
|
return;
|
|
}
|
|
chamber_TankLowerFloatSwitchStateCurrent = GetInSwitchState(WATER_BANK_FLOAT_SWITCH_LOWER);
|
|
chamber_TankUpperFloatSwitchStateCurrent = GetInSwitchState(WATER_BANK_FLOAT_SWITCH_UPPER);
|
|
Serial.print("Water Tank lower float switch: "); Serial.println(chamber_TankLowerFloatSwitchStateCurrent);
|
|
Serial.print("Water Tank upper float switch: "); Serial.println(chamber_TankUpperFloatSwitchStateCurrent);
|
|
//tank penampung harus penuh dulu baru mau dong
|
|
if (chamber_TankLowerFloatSwitchStateCurrent && chamber_TankUpperFloatSwitchStateCurrent){
|
|
//cek jika chamber kosong total
|
|
if (!chamber_SterilizationLowerFloatSwitchStateCurrent && !chamber_SterilizationUpperFloatSwitchStateCurrent){
|
|
//kosong total
|
|
chamberTick = millis();
|
|
chamberState = CHAMBER_STATE_CHECK_FILLING_TO_LOWER;
|
|
Serial.println("CHAMBER_STATE_START_FILLING -> CHAMBER_STATE_CHECK_FILLING_TO_LOWER");
|
|
}else if (chamber_SterilizationLowerFloatSwitchStateCurrent && !chamber_SterilizationUpperFloatSwitchStateCurrent){
|
|
//ada sedikit, mayan
|
|
chamberTick = millis();
|
|
chamberState = CHAMBER_STATE_CHECK_FILLING_TO_UPPER;
|
|
Serial.println("CHAMBER_STATE_START_FILLING -> CHAMBER_STATE_CHECK_FILLING_TO_UPPER");
|
|
}else{
|
|
//float switch error ini hadeh
|
|
chamberError = true;
|
|
chamberErrorString = "Float switch sterilisasi error.";
|
|
chamberState = CHAMBER_STATE_IDLE;
|
|
Serial.print("Error: ");
|
|
Serial.println(chamberErrorString);
|
|
Serial.println("CHAMBER_STATE_START_FILLING -> CHAMBER_STATE_IDLE");
|
|
return;
|
|
}
|
|
}else{
|
|
chamberError = true;
|
|
chamberErrorString = "Tangki penampung air harus penuh dahulu untuk dapat memulai pengisian tangki sterilisasi.";
|
|
Serial.print("Error: ");
|
|
Serial.println(chamberErrorString);
|
|
if (chamberAutomatic){
|
|
chamberState = CHAMBER_STATE_IDLE;
|
|
Serial.println("CHAMBER_STATE_START_FILLING -> CHAMBER_STATE_IDLE");
|
|
}else{
|
|
chamberState = CHAMBER_STATE_NONE;
|
|
Serial.println("CHAMBER_STATE_START_FILLING -> CHAMBER_STATE_NONE");
|
|
}
|
|
return;
|
|
}
|
|
};
|
|
break;
|
|
case CHAMBER_STATE_CHECK_FILLING_TO_LOWER:{
|
|
//waiting for filling into lower level, or stop when timeout
|
|
//switch on the pump
|
|
if (!GetSwitchState(STERILIZATION_CHAMBER_FILL_PUMP_SWITCH)){
|
|
Serial.println("ChamberSystemRoutine: TURN ON FILL PUMP SWITCH");
|
|
SetSwitchState(STERILIZATION_CHAMBER_FILL_PUMP_SWITCH, true);
|
|
}
|
|
//monitoring water level or timed out
|
|
bool lowerSwitchState = GetInSwitchState(STERILIZATION_CHAMBER_FLOAT_SWITCH_LOWER);
|
|
bool upperSwitchState = GetInSwitchState(STERILIZATION_CHAMBER_FLOAT_SWITCH_UPPER);
|
|
//chamber_TankLowerFloatSwitchStateCurrent = GetInSwitchState(WATER_BANK_FLOAT_SWITCH_LOWER);
|
|
//if (lowerSwitchState || upperSwitchState || !chamber_TankLowerFloatSwitchStateCurrent){
|
|
if (lowerSwitchState || upperSwitchState){
|
|
//check if lower float switch on
|
|
//try to fill till full
|
|
ClearChamberError();
|
|
chamberTick = millis();
|
|
chamberState = CHAMBER_STATE_CHECK_FILLING_TO_UPPER;
|
|
Serial.println("CHAMBER_STATE_CHECK_FILLING_TO_LOWER -> CHAMBER_STATE_CHECK_FILLING_TO_UPPER");
|
|
}else{
|
|
//check if timed out
|
|
if (millis()-chamberTick>=chamberExpectedTimeToFilledLower){
|
|
chamberError = true;
|
|
chamberErrorCode = CHAMBER_ERROR_LOWER_FLOAT_SWITCH;
|
|
chamberErrorString = "Tank 2 insufficient input water, or lower float switch error, or input pump error.";
|
|
Serial.println("Chamber Error -> CHAMBER_ERROR_LOWER_FLOAT_SWITCH");
|
|
if (chamberAutomatic){
|
|
chamberState = CHAMBER_STATE_IDLE;
|
|
Serial.println("CHAMBER_STATE_CHECK_FILLING_TO_LOWER -> CHAMBER_STATE_IDLE");
|
|
}else{
|
|
chamberState = CHAMBER_STATE_NONE;
|
|
Serial.println("CHAMBER_STATE_CHECK_FILLING_TO_LOWER -> CHAMBER_STATE_NONE");
|
|
}
|
|
}
|
|
}
|
|
};
|
|
break;
|
|
case CHAMBER_STATE_CHECK_FILLING_TO_UPPER:{
|
|
//waiting for filling into lower level, or stop when timeout
|
|
//switch on the pump
|
|
if (!GetSwitchState(STERILIZATION_CHAMBER_FILL_PUMP_SWITCH)){
|
|
Serial.println("ChamberSystemRoutine: TURN ON FILL PUMP SWITCH");
|
|
SetSwitchState(STERILIZATION_CHAMBER_FILL_PUMP_SWITCH, true);
|
|
}
|
|
//monitoring water level or timed out
|
|
bool upperSwitchState = GetInSwitchState(STERILIZATION_CHAMBER_FLOAT_SWITCH_UPPER);
|
|
chamber_TankLowerFloatSwitchStateCurrent = GetInSwitchState(WATER_BANK_FLOAT_SWITCH_LOWER);
|
|
if (upperSwitchState || (!chamber_TankLowerFloatSwitchStateCurrent)){
|
|
//check if upper float switch on or chamber's water below switch
|
|
SetSwitchState(STERILIZATION_CHAMBER_FILL_PUMP_SWITCH, false); //matiin pompa
|
|
ClearChamberError();
|
|
chamberTick = millis();
|
|
chamberState = CHAMBER_STATE_STERILIZING;
|
|
Serial.println("CHAMBER_STATE_CHECK_FILLING_TO_UPPER -> CHAMBER_STATE_STERILIZING");
|
|
}else{
|
|
//check if timed out
|
|
if (millis()-chamberTick>=chamberExpectedTimeToFilledUpper){
|
|
SetSwitchState(STERILIZATION_CHAMBER_FILL_PUMP_SWITCH, false); //matiin pompa
|
|
chamberError = true;
|
|
chamberErrorCode = CHAMBER_ERROR_UPPER_FLOAT_SWITCH;
|
|
chamberErrorString = "Tank 2 insufficient input water, or upper float switch error, or input pump error.";
|
|
Serial.println("Chamber Error -> CHAMBER_ERROR_UPPER_FLOAT_SWITCH");
|
|
if (chamberAutomatic){
|
|
chamberState = CHAMBER_STATE_IDLE;
|
|
Serial.println("CHAMBER_STATE_CHECK_FILLING_TO_UPPER -> CHAMBER_STATE_IDLE");
|
|
}else{
|
|
chamberState = CHAMBER_STATE_NONE;
|
|
Serial.println("CHAMBER_STATE_CHECK_FILLING_TO_UPPER -> CHAMBER_STATE_NONE");
|
|
}
|
|
}
|
|
}
|
|
};
|
|
break;
|
|
case CHAMBER_STATE_STERILIZING:{
|
|
//make sure turn off filling in and filling out pump
|
|
if (GetSwitchState(STERILIZATION_CHAMBER_FILL_PUMP_SWITCH)) SetSwitchState(STERILIZATION_CHAMBER_FILL_PUMP_SWITCH, false);
|
|
if (GetSwitchState(STERILIZED_CHAMBER_FILL_PUMP_SWITCH)) SetSwitchState(STERILIZED_CHAMBER_FILL_PUMP_SWITCH, false);
|
|
//if inverter not turned -> switch it first, but wait for 2 seconds
|
|
if (!GetSwitchState(INVERTER_SWITCH)){
|
|
//make sure turn off ozone and circulation
|
|
if (GetSwitchState(STERILIZATION_OZONE_AND_UV_SWITCH)) SetSwitchState(STERILIZATION_OZONE_AND_UV_SWITCH, false);
|
|
if (GetSwitchState(STERILIZATION_CHAMBER_CIRCULATION_PUMP_SWITCH)) SetSwitchState(STERILIZATION_CHAMBER_CIRCULATION_PUMP_SWITCH, false);
|
|
chamberInverterStartupTick = millis();
|
|
SetSwitchState(INVERTER_SWITCH, true);
|
|
Serial.println("Starting up the inveter.");
|
|
return;
|
|
}else{
|
|
if ((millis()-chamberInverterStartupTick)<2000){
|
|
chamberTick = millis(); //keep reset it
|
|
return;
|
|
}
|
|
}
|
|
//turn on ozone and circulation pump
|
|
if (!GetSwitchState(STERILIZATION_OZONE_AND_UV_SWITCH)) SetSwitchState(STERILIZATION_OZONE_AND_UV_SWITCH, true);
|
|
if (!GetSwitchState(STERILIZATION_CHAMBER_CIRCULATION_PUMP_SWITCH)) SetSwitchState(STERILIZATION_CHAMBER_CIRCULATION_PUMP_SWITCH, true);
|
|
|
|
//wait till done, or if water is empty by accident (leaking) => back to idle with error state
|
|
bool lowerSwitchState = GetInSwitchState(STERILIZATION_CHAMBER_FLOAT_SWITCH_LOWER);
|
|
if (!lowerSwitchState){
|
|
//wah error atau bocor nih
|
|
ChamberTurnOffAllSwitch(false); //turn off all switch including inverter
|
|
chamberError = true;
|
|
chamberErrorCode = CHAMBER_ERROR_LOWER_FLOAT_SWITCH_OR_LEAKED;
|
|
chamberErrorString = "Tank 2 leaked, or lower float switch error";
|
|
Serial.print("Error: ");
|
|
Serial.println(chamberErrorString);;
|
|
chamberState = CHAMBER_STATE_NONE;
|
|
Serial.println("CHAMBER_STATE_STERILIZING -> CHAMBER_STATE_NONE");
|
|
return;
|
|
}
|
|
//tunggu hingga selesai sterilisasi
|
|
if ((millis()-chamberTick)>=chamberSterilizationOzoneDuration){
|
|
chamberPostUvTick = millis();//reset uv post tick too
|
|
bool keepInverter = chamberPostUvEnable && (chamberPostUvDuration>0);
|
|
ChamberTurnOffAllSwitch(keepInverter);
|
|
chamberTick = millis(); //keep reset it
|
|
chamberState = CHAMBER_STATE_START_UNLOAD;
|
|
Serial.println("CHAMBER_STATE_STERILIZING -> CHAMBER_STATE_START_UNLOAD");
|
|
}
|
|
};
|
|
break;
|
|
case CHAMBER_STATE_START_UNLOAD:{
|
|
bool lowerSwitchState = GetInSwitchState(STERILIZED_CHAMBER_FLOAT_SWITCH_LOWER);
|
|
bool upperSwitchState = GetInSwitchState(STERILIZED_CHAMBER_FLOAT_SWITCH_LOWER);
|
|
chamberTick = millis(); //reset it
|
|
if (!lowerSwitchState && !upperSwitchState){
|
|
//fill to lower first
|
|
chamberState = CHAMBER_STATE_START_UNLOAD_TO_LOWER;
|
|
Serial.println("CHAMBER_STATE_START_UNLOAD -> CHAMBER_STATE_START_UNLOAD_TO_LOWER");
|
|
}else if (lowerSwitchState && !upperSwitchState){
|
|
//fill to upper
|
|
chamberState = CHAMBER_STATE_START_UNLOAD_TO_UPPER;
|
|
Serial.println("CHAMBER_STATE_START_UNLOAD -> CHAMBER_STATE_START_UNLOAD_TO_UPPER");
|
|
}else if (lowerSwitchState && upperSwitchState){
|
|
//already full
|
|
ChamberTurnOffAllSwitch(false); //turn off all switch including inverter
|
|
if (chamberAutomatic){
|
|
chamberState = CHAMBER_STATE_IDLE;
|
|
Serial.println("CHAMBER_STATE_START_UNLOAD -> CHAMBER_STATE_IDLE");
|
|
}else{
|
|
chamberState = CHAMBER_STATE_NONE;
|
|
Serial.println("CHAMBER_STATE_START_UNLOAD -> CHAMBER_STATE_NONE");
|
|
}
|
|
chamberSterilizationSuccess = true;
|
|
}else{
|
|
//float switch error
|
|
ChamberTurnOffAllSwitch(false); //turn off all switch including inverter
|
|
chamberError = true;
|
|
chamberErrorCode = CHAMBER_ERROR_STORAGE_LOWER_FLOAT_SWITCH;
|
|
chamberErrorString = "Tank 3 float switch error";
|
|
Serial.print("Error: ");
|
|
Serial.println(chamberErrorString);;
|
|
chamberState = CHAMBER_STATE_NONE;
|
|
Serial.println("CHAMBER_STATE_START_UNLOAD -> CHAMBER_STATE_NONE");
|
|
return;
|
|
}
|
|
//switch post uv when it reach at least lowest level and used
|
|
if (chamberPostUvEnable && lowerSwitchState){
|
|
chamberPostUvTick = millis();//reset uv post tick too
|
|
if (chamberPostUvEnable && (chamberPostUvDuration>0)){
|
|
//turn on uv
|
|
SetSwitchState(STERILIZED_UV_SWITCH, true);
|
|
}
|
|
}
|
|
};
|
|
break;
|
|
case CHAMBER_STATE_START_UNLOAD_TO_LOWER:{
|
|
//switch on the pump
|
|
if (!GetSwitchState(STERILIZED_CHAMBER_FILL_PUMP_SWITCH)){
|
|
Serial.println("ChamberSystemRoutine: TURN ON OUT PUMP SWITCH");
|
|
SetSwitchState(STERILIZED_CHAMBER_FILL_PUMP_SWITCH, true);
|
|
}
|
|
bool lowerSwitchState = GetInSwitchState(STERILIZED_CHAMBER_FLOAT_SWITCH_LOWER);
|
|
bool upperSwitchState = GetInSwitchState(STERILIZED_CHAMBER_FLOAT_SWITCH_UPPER);
|
|
if (lowerSwitchState || upperSwitchState){
|
|
//check if lower float switch on
|
|
//try to fill till full
|
|
ClearChamberError();
|
|
chamberTick = millis();
|
|
chamberState = CHAMBER_STATE_START_UNLOAD_TO_UPPER;
|
|
Serial.println("CHAMBER_STATE_START_UNLOAD_TO_LOWER -> CHAMBER_STATE_START_UNLOAD_TO_UPPER");
|
|
}else{
|
|
//check if timed out
|
|
if (millis()-chamberTick>=chamberExpectedTimeToUnloadFilledLower){
|
|
ChamberTurnOffAllSwitch(false); //turn off all switch including inverter
|
|
chamberError = true;
|
|
chamberErrorCode = CHAMBER_ERROR_STORAGE_LOWER_FLOAT_SWITCH_OR_NO_WATER;
|
|
chamberErrorString = "Tank 2 leaked, or Tank 3 lower float switch error, or output pump error.";
|
|
Serial.println("Chamber Error -> CHAMBER_ERROR_STORAGE_LOWER_FLOAT_SWITCH_OR_NO_WATER");
|
|
if (chamberAutomatic){
|
|
chamberState = CHAMBER_STATE_IDLE;
|
|
Serial.println("CHAMBER_STATE_CHECK_FILLING_TO_LOWER -> CHAMBER_STATE_IDLE");
|
|
}else{
|
|
chamberState = CHAMBER_STATE_NONE;
|
|
Serial.println("CHAMBER_STATE_CHECK_FILLING_TO_LOWER -> CHAMBER_STATE_NONE");
|
|
}
|
|
return;
|
|
}
|
|
//check if tank 2 empty. indicate leaking
|
|
chamber_SterilizationLowerFloatSwitchStateCurrent = GetInSwitchState(STERILIZATION_CHAMBER_FLOAT_SWITCH_LOWER);
|
|
if (!chamber_SterilizationLowerFloatSwitchStateCurrent){
|
|
ChamberTurnOffAllSwitch(false); //turn off all switch including inverter
|
|
chamberError = true;
|
|
chamberErrorCode = CHAMBER_ERROR_LOWER_FLOAT_SWITCH;
|
|
chamberErrorString = "Tank 2 leaked or lower float switch error";
|
|
Serial.println("Chamber Error -> CHAMBER_ERROR_LOWER_FLOAT_SWITCH");
|
|
if (chamberAutomatic){
|
|
chamberState = CHAMBER_STATE_IDLE;
|
|
Serial.println("CHAMBER_STATE_CHECK_FILLING_TO_LOWER -> CHAMBER_STATE_IDLE");
|
|
}else{
|
|
chamberState = CHAMBER_STATE_NONE;
|
|
Serial.println("CHAMBER_STATE_CHECK_FILLING_TO_LOWER -> CHAMBER_STATE_NONE");
|
|
}
|
|
return;
|
|
}
|
|
}
|
|
//manage post uv
|
|
if (chamberPostUvEnable && lowerSwitchState){
|
|
chamberPostUvTick = millis();//reset uv post tick too
|
|
if (chamberPostUvEnable && (chamberPostUvDuration>0)){
|
|
//turn on uv
|
|
SetSwitchState(STERILIZED_UV_SWITCH, true);
|
|
}
|
|
}
|
|
};
|
|
break;
|
|
case CHAMBER_STATE_START_UNLOAD_TO_UPPER:{
|
|
//switch on the pump
|
|
if (!GetSwitchState(STERILIZED_CHAMBER_FILL_PUMP_SWITCH)){
|
|
Serial.println("ChamberSystemRoutine: TURN ON OUT PUMP SWITCH");
|
|
SetSwitchState(STERILIZED_CHAMBER_FILL_PUMP_SWITCH, true);
|
|
}
|
|
//manage post uv
|
|
bool lowerSwitchState = GetInSwitchState(STERILIZED_CHAMBER_FLOAT_SWITCH_LOWER);
|
|
if (chamberPostUvEnable && lowerSwitchState){
|
|
if (chamberPostUvEnable && (chamberPostUvDuration>0) && (!GetSwitchState(STERILIZED_UV_SWITCH) && (millis()-chamberPostUvTick<chamberPostUvDuration))){
|
|
//turn on uv but do not update the timer
|
|
SetSwitchState(STERILIZED_UV_SWITCH, true);
|
|
}
|
|
}
|
|
//bool lowerSwitchState = GetInSwitchState(STERILIZED_CHAMBER_FLOAT_SWITCH_LOWER);
|
|
bool upperSwitchState = GetInSwitchState(STERILIZED_CHAMBER_FLOAT_SWITCH_UPPER);
|
|
chamber_SterilizationLowerFloatSwitchStateCurrent = GetInSwitchState(STERILIZATION_CHAMBER_FLOAT_SWITCH_LOWER);
|
|
if (upperSwitchState || !chamber_SterilizationLowerFloatSwitchStateCurrent){
|
|
chamberSterilizationSuccess = false; //done!
|
|
ChamberTurnOffAllSwitch(true); //turn off all switch excluding inverter
|
|
ClearChamberError();
|
|
chamberTick = millis();
|
|
if (chamberAutomatic){
|
|
chamberState = CHAMBER_STATE_IDLE;
|
|
Serial.println("CHAMBER_STATE_START_UNLOAD_TO_UPPER -> CHAMBER_STATE_IDLE");
|
|
}else{
|
|
chamberState = CHAMBER_STATE_NONE;
|
|
Serial.println("CHAMBER_STATE_START_UNLOAD_TO_UPPER -> CHAMBER_STATE_NONE");
|
|
}
|
|
}else{
|
|
//check if timed out
|
|
if (millis()-chamberTick>=chamberExpectedTimeToUnloadFilledUpper){
|
|
ChamberTurnOffAllSwitch(false); //turn off all switch including inverter
|
|
chamberError = true;
|
|
chamberErrorCode = CHAMBER_ERROR_STORAGE_UPPER_FLOAT_SWITCH_OR_NO_WATER;
|
|
chamberErrorString = "Tank 2 leaked, or Tank 1 upper float switch error, or output pump error.";
|
|
Serial.println("Chamber Error -> CHAMBER_ERROR_STORAGE_UPPER_FLOAT_SWITCH_OR_NO_WATER");
|
|
if (chamberAutomatic){
|
|
chamberState = CHAMBER_STATE_IDLE;
|
|
Serial.println("CHAMBER_STATE_CHECK_FILLING_TO_UPPER -> CHAMBER_STATE_IDLE");
|
|
}else{
|
|
chamberState = CHAMBER_STATE_NONE;
|
|
Serial.println("CHAMBER_STATE_CHECK_FILLING_TO_UPPER -> CHAMBER_STATE_NONE");
|
|
}
|
|
return;
|
|
}
|
|
}
|
|
|
|
};
|
|
break;
|
|
}
|
|
}
|
|
//==========================================================================
|
|
|
|
void StartChamberSystem(bool automatic, bool forceRunIfAutomatic = false, bool usePostUv=false){
|
|
ClearChamberError();
|
|
chamberAutomatic = automatic;
|
|
chamberPostUvEnable = usePostUv;
|
|
chamberSterilizationSuccess = false;
|
|
|
|
bool runNow = false;
|
|
|
|
if (chamberAutomatic){
|
|
RefreshInSwitchState();
|
|
chamberState = CHAMBER_STATE_IDLE;
|
|
runNow = forceRunIfAutomatic;
|
|
if (!runNow) Serial.println("StartChamberSystem -> CHAMBER_STATE_IDLE");
|
|
}else{
|
|
runNow = true;
|
|
}
|
|
|
|
if (runNow){
|
|
RefreshInSwitchState();
|
|
chamberState = CHAMBER_STATE_START_FILLING;
|
|
Serial.println("StartChamberSystem -> CHAMBER_STATE_START_FILLING");
|
|
}
|
|
}
|
|
|
|
void StopChamberSystem(){
|
|
ClearChamberError();
|
|
chamberState = CHAMBER_STATE_NONE;
|
|
ChamberSystemRoutine(); //call it once
|
|
ChamberTurnOffAllSwitch(false);//make sure to turn off all
|
|
}
|
|
|
|
void ChamberSetPostUvDuration(uint32_t v){
|
|
chamberPostUvDuration = v;
|
|
}
|
|
|
|
void ChamberSetSterlizationDuration(uint32_t v){
|
|
chamberSterilizationOzoneDuration = v;
|
|
}
|